EasyManua.ls Logo

Omron V430-F Series - ISO;IEC 29158 Symbol Quality Output 2

Omron V430-F Series
404 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 7-45
I/O Parameters
ISO/IEC 29158 Symbol Quality Output 1
Note: Output On under Output 1 Parameters must be set to Symbol Quality for this output
to function.
Automatic identification and data capture – Direct Part Mark (DMP) Quality
Supported symbologies:
Minimum Resolution: 6.0 Pixels Per Element
Output on Overall Grade
Overall Grade Threshold
DataMatrix ECC200
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, drives Output if grade is under Overall Grade Threshold.
Serial Cmd: <K890, output on overall grade, overall grade threshold, cell contrast, cell
contrast threshold, cell modulation, cell modulation threshold, fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Sets the threshold for driving the output.
Definition: Conforms to ISO/IEC 29158 symbol quality grading (A,B,C,D).
Serial Cmd: <K890, output on overall grade, overall grade threshold, cell contrast, cell
contrast threshold, cell modulation, cell modulation threshold, fixed pattern
damage, fixed pattern damage threshold, axial non-uniformity, axial non-
uniformity threshold, grid non-uniformity, grid non-uniformity threshold,
unused ECC, unused ECC threshold>
Default: Grade B
Options: 0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A