Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 7-63
I/O Parameters
EZ Trax Output
Transfer Port
Image Mode
Good Read
Outputs the first Good Read image in the read cycle. The image file will immediately follow
the symbol data.
Usage: Useful for when you want to configure EZ Trax output using serial commands
instead of the EZ Trax graphic interface.
Definition: When EZ Trax output is enabled, the imager will attempt to output all
enabled EZ Trax options. EZ Trax will not function unless enabled.
Serial Cmd:
<
status
,transfer port,image mode,image format,image quality,object info
enable
,grade enable
>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Selects the communication port that will be used to transfer image files.
Serial Cmd:
<
K757,
status,
transfer port
,image mode,image format,JPEG quality,object
info enable
,grade enable
>
Default: RS-232
Options: 0 = RS-232
3 = Ethernet TCP Port 1
4 = Ethernet TCP Port 2
Definition: Determines which read cycle condition triggers image file output.
Serial Cmd:
<
K757,
status,transfer port,
image mode
,image format,image quality,object
info enable
,grade enable
>
Default: Disabled
Options: 0 = Disabled
1 = Good Read
2 = No Read
3 = No Read and Good Read
4 = Mismatch