7-8 Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Symbol Data Output
Symbology Identifier Status
Disabled
When set to Disabled, the symbol data output does not contain symbology information.
Enabled
When set to Enabled, the symbol data output contains a three-character symbology
identifier sequence.
Serial Cmd:
<
K705,
symbol data output status,when to output
,symbology identifier status
>
Default: Disabled
Options: 0 = Disabled 1 = Enabled