EasyManua.ls Logo

Omron V430-F Series - Page 106

Omron V430-F Series
404 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 5-9
Read Cycle
Serial Data
Note: In Serial Data, sending a non-delimited start serial character will start a read cycle;
however, a non-delimited stop serial character has no effect.
Serial Data and Edge
Note: In Serial Data, sending a non-delimited start serial character will start a read cycle;
however, a non-delimited stop serial character has no effect.
Continuous Read Auto
Usage: Serial Data is effective in a highly controlled environment where the host
knows precisely when the object is in the field of view. It is also useful in
determining if a No-Read has occurred.
Definition: In Serial Data, the reader accepts an ASCII character from the host or
controlling device as a trigger to start a read cycle. A Serial Data trigger
behaves the same as an External Edge trigger.
Serial commands are entered inside angle brackets, as shown here: <t>.
Serial Cmd: <K200,4>
Usage: Serial Data or External Edge is seldom used but can be useful in an
application that primarily uses an external sensing device but occasionally
needs to be triggered manually.
Definition: In this mode the reader accepts either a serial ASCII character or an external
trigger pulse to start the read cycle.
Serial Cmd: <K200,5>
Definition: Behaves identically to Continuous Read but maintains optimal self-adjusting
photometry and focus parameters. As a result, the photometry parameters
(Exposure and Gain) in the <K541> command as well as the focus param-
eter in the <K525> command are continuously updated with the optimal
configuration parameters. In this mode, the illumination does not strobe, but
instead is always active, as images are continuously captured. If the
<K525,,,Auto Focus Mode>
field is set to
1
, and if there is a series of no-reads,
this mode will self-start a focus pass. <K525,,,, # noreads> defines how
many no-reads must occur before the focus pass will start.
Serial Cmd: <K200,6>