Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 5-21
Read Cycle
Number of Continuous Captures
Images per Read Cycle Limit
Read Cycle History
Definition:
Specifies the number of captures to process in Continuous Capture mode.
Serial Cmd:
<
K241,
capture mode,
number of captures,rapid capture mode,number of
continuous
captures
,images per read cycle limit,read cycle history>
Default: 2
Options: 1 and 255
Definition:
Specifies the number of captures to process in a read cycle.
Serial Cmd:
<
K241,
capture mode,
number of captures,rapid capture mode,number of
continuous
captures,
images per read cycle limit
,read cycle history>
Default: 10
Options: 3 and 255
Definition:
Specifies the number of images that can be stored in read cycle history.
Serial Cmd:
<
K241,
capture mode,
number of captures,rapid capture mode,number of
continuous
captures,
images per read cycle limit
,read cycle history>
Default: 10
Options: 0 and 255