Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 6-21
Symbologies
Large Intercharacter Gap (Codabar)
Fixed Symbol Length Status (Codabar)
Symbol Length (Codabar)
Definition: When disabled, the spaces between characters, or the “intercharacter
gap”, are ignored during the decode process.
Note: If the intercharacter space is large enough to be considered a margin,
the symbol will not decode, regardless of this parameter’s setting.
Serial Cmd: <K471,status,start/stop match,start/stop output,large intercharacter
gap,fixed symbol length status,symbol length,check character type,check
character output>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: When disabled, the reader will accept any Codabar symbol provided it
doesn’t exceed the system’s maximum capabilities.
When enabled, the reader will reject any Codabar symbol that doesn’t
match the fixed length.
Serial Cmd:
<
K471,
status,start/stop match,start/stop output,large intercharacter gap,
fixed
symbol length status
,symbol length,check character type,check character
output>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: This is the value against which all Codabar symbol lengths will be compared.
Serial Cmd: <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed
symbol length status,symbol length,check character type,check character
output>
Default: 10
Options: 1 to 64

Table of Contents

Other manuals for Omron V430-F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V430-F Series and is the answer not in the manual?

Omron V430-F Series Specifications

General IconGeneral
BrandOmron
ModelV430-F Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals