7-40 Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
ISO/IEC 15416 Symbol Quality Output 1
Contrast Threshold
Min Reflectance
Min Reflectance Threshold
Usage: Sets the threshold for driving the output.
Definition: Conforms to ISO/IEC 15416 symbol quality grading (A,B,C,D).
Serial Cmd: <K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet Zone,
quiet zone threshold >
Default: Grade B
Options: 0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, drives Output if grade is under Min Reflectance Threshold.
Serial Cmd: <K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet Zone,
quiet zone threshold >
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Sets the threshold for driving the output.
Definition: Conforms to ISO/IEC 15416 symbol quality grading (A,B,C,D).
Serial Cmd: <K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet Zone,
quiet zone threshold >
Default: Grade B