7-42 Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
ISO/IEC 15416 Symbol Quality Output 1
Modulation Threshold
Defects
Defects Threshold
Serial Cmd: <K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet Zone,
quiet zone threshold >
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Sets the threshold for driving the output.
Definition: Conforms to ISO/IEC 15416 symbol quality grading (A,B,C,D).
Serial Cmd: <K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet Zone,
quiet zone threshold >
Default: Grade B
Options: 0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, drives Output if grade is under Defects Threshold.
Serial Cmd: <K880, output on overall grade, overall grade threshold, edge determina-
tion, edge determination threshold, decode, decode threshold, contrast,
contrast threshold, min reflectance, min reflectance threshold, min edge
contrast, min edge contrast threshold, modulation, modulation threshold,
defects, defects threshold, decodability, decodability threshold, quiet Zone,
quiet zone threshold >
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Sets the threshold for driving the output.
Definition: Conforms to ISO/IEC 15416 symbol quality grading (A,B,C,D).