Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 11-9
Configuration Database
Morphology Operator
Morphology Size
Definition: Specifies the morphology operation (erode, dilate, open, close) used to
pre-process the WOI.
Serial Cmd:
<
K255,
index,exposure,gain,focal distance,pixel binning,row pointer,column pointer,
row depth,column width,symbology,
morphology operator
,morphology size>
Default: Disabled
Definition:
Specifies the morphology operator size to apply:
Small (3 x 3)
,
Medium (5 x 5)
,
and Large (7 x 7).
Serial Cmd:
<
K255,
index,exposure,gain,focal distance,pixel binning,row pointer,column pointer,
row depth,column width,symbology,morphology operator,
morphology size
>
Default: Small(3 x 3)