EasyManuals Logo

Omron V430-F Series User Manual

Omron V430-F Series
404 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #338 background imageLoading...
Page #338 background image
Auto Focus Multi Code Reader V430-series User’s Manual (Z392) 13-7
Utilities
Counters by Serial Command
No-Read Counter
Sending <N> displays the total number of No-Reads that have occurred since the last reset.
No-Read Counter Reset
Sending <O> sets the No-Read Counter to 0.
Trigger Counter
Sending <T> displays the total number of triggers since the last reset.
Trigger Counter Reset
Sending <U> sets the trigger counter to 0.
Good Read/Match Counter (or Good Read Counter)
Sending <V> displays the total number of good reads matching the master symbol, or, if
Master Symbol is not enabled, the number of good reads since the last reset. This counter
is always enabled, but will only work as a match count when Master Symbol is enabled. If
Master Symbol is not enabled, this counter records the number of good reads. This count
can be requested at any time.
Good Read/Match Counter Reset
Sending <W> sets the Match Counter to 0.
Mismatch Counter
Sending <X> displays the number of decoded symbols since the last reset that do not
match the master symbol.
Mismatch Counter Reset
Sending <Y> sets the Mismatch Counter to 0.

Table of Contents

Other manuals for Omron V430-F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V430-F Series and is the answer not in the manual?

Omron V430-F Series Specifications

General IconGeneral
BrandOmron
ModelV430-F Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals