13-12 Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Master Database
Enter Master Symbol Data
Usage: Allows you to enter master symbol data for any enabled master symbol index
number (1 to 10), provided the total number of characters does not exceed
the maximum allowed.
Serial Cmd: <K231,master symbol number,master symbol data>
Options: Enter data for 1 to 10 symbols (any combination of ASCII text up to the
maximum allowed.
For example, to enter data for master symbol 9, after making certain that
master
symbol database size is enabled for 9 or more symbols, send
<K231,9,data>
.
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex values.
Caution:
If no data is entered, the existing data will be deleted.
ESP: 1. Open the Utilities menu.
2. Set the number of master symbols you want to create in Master Symbol
Database Size.
3. Double-click on each symbol number you want to set up and copy, or type
your data in the popup dialog and click OK.
4. When all your data has been entered, click the Send Database to Reader
button.

Table of Contents

Other manuals for Omron V430-F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V430-F Series and is the answer not in the manual?

Omron V430-F Series Specifications

General IconGeneral
BrandOmron
ModelV430-F Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals