4-6 Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Calibration Options
Symbol Type
Disabled
When this feature is disabled, only the current enabled symbologies will be considered
during the calibration process.
Enabled
When this feature is enabled, autodiscrimination is in effect during the calibration process.
All supported symbologies except PDF417 and Pharmacode will be attempted during
calibration. Any new symbologies successfully decoded during calibration will remain
enabled at the end of the process. All enabled symbologies will remain enabled. For
example, assume that only Code 39 is enabled at the beginning of calibration. If a Code
128 symbol is decoded during calibration, then Code 128 as well as Code 39 will be enabled.
Serial Cmd: <K529,gain,exposure,
focus position
,symbol type,WOI framing,WOI
margin,line scan height,processing>
Default: Enabled
Options: 0 = Disabled 1 = Enabled