4.8 System [2]
Feature Guide 443
Default
Disable
Value Range
Disable: No port
Slot 01:DHLC4: Initially installed 4 Super Hybrid ports
Slot nn:SLC4: Ports 1 to 4 of the SLC4 card (nn=slot number)
Slot nn:SLC8 1-4: Ports 1 to 4 of the SLC8 card (nn=slot number)
Slot nn:SLC8 5-8: Ports 5 to 8 of the SLC8 card (nn=slot number)
Slot nn:HLC4: Ports 1 to 4 of the HLC4 card (nn=slot number)
Programming References
4.10.1 Wired Extension—Extension Settings [4-1-1]—Option 7—Extension Caller ID
Feature Guide References
1.16.1 Caller ID
Extension Caller ID Modulation Type
Specifies the modulation frequency to be used when sending Caller ID information to an SLT.
Default
Bell202(Bellcore)
Value Range
V.23(ETSI), Bell202(Bellcore)
Programming References
None
Feature Guide References
1.16.1 Caller ID
Channel Seizure Signal bits
Specifies the number of seizure bits to send when sending Caller ID information to an SLT.
Default
300 bits
Value Range
10 × n (n=3–40) bits
Programming References
None
Feature Guide References
1.16.1 Caller ID