4.8 System [2]
444 Feature Guide
Mark Signal bits
Specifies the number of mark bits to send when sending Caller ID information to an SLT.
Default
180 bits
Value Range
10 × n (n=3–40) bits
Programming References
None
Feature Guide References
1.16.1 Caller ID
Channel Seizure Wait Time
Specifies the length of time the PBX waits before starting to send the seizure signal following the first ring
when sending Caller ID information to an SLT.
Default
512 ms
Value Range
64 × n (n=5–35) ms
Programming References
None
Feature Guide References
1.16.1 Caller ID
Additional Local Trunk Access Code to Extension Caller ID
Enables the PBX to automatically add a Trunk Access number to the received telephone number when
sending a Caller ID number of an incoming trunk call to an SLT.
Default
Enable
Value Range
Disable, Enable
Programming References
None