BELL_CORE_PATTERN3_TIMING
Value Format Comma-separated Integer
Description Specifies the cadence, in milliseconds, of pattern ID 3, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2…) separated by
commas.
Value Range 0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
Default Value 400,200,400,200,800,4000
BELL_CORE_PATTERN4_TIMING
Value Format Comma-separated Integer
Description Specifies the cadence, in milliseconds, of pattern ID 4, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2…) separated by
commas.
Value Range 0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
Default Value 300,200,1000,200,300,4000
BELL_CORE_PATTERN5_TIMING
Value Format Integer
Description Specifies the cadence, in milliseconds, of pattern ID 5, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2…) separated by
commas.
Value Range 0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
Default Value 500