A-24 Serial Communications 590 Series DC Digital Drive
Block 2
PNO (ID) (MN) TAG DATA FORMAT LIMITS ACCESS DESCRIPTION
BINARY ASCII BIT ASCII BINARY MIN TO MAX
16 10 050 - 21 xxx.xx R/O Anin 1 (A2)
17 11 051 - 21 xxx.xx R/O Anin 2 (A3)
18 12 052 - 21 xxx.xx R/O Anin 3 (A4)
19 13 053 - 21 xxx.xx R/O Anin 4 (A5)
20 14 054 - 21 xxx.xx R/O Anin 5 (A6)
21 15 067 - 21 xxx.xx R/O Actual Pos I Lim
22 16 061 - 21 xxx.xx R/O Actual Neg I Lim
23 17 040 - 23 xxxxx R/O
- 068 0 0/1 Start Input
- 069 1 0/1 Jog Input
- 070 2 0/1 Enable Input
- 071 3 0/1 Digital Input 1
- 072 4 0/1 Digital Input 2
- 073 5 0/1 Digital Input 3
- - 6 0/1 Program Stop Input
- - 7 0/1 Coast Stop Input
- 074 8 0/1 Digital Output 1
- 075 9 0/1 Digital Output 2
- 076 10 0/1 Digital Output 3
- - 11-15 0/1 Reserved