C-14 Parameter Specification Tables 590 Series DC Digital Drive
Tag Mn Function Block Name Parameter Name Minimum Maximum Default Units Range Notes
340 jg miniLINK VALUE 2 -300.00 300.00 0.00 % V1 W0
341 jh miniLINK VALUE 3 -300.00 300.00 0.00 % V1 W0
342 ji miniLINK VALUE 4 -300.00 300.00 0.00 % V1 W0
343 jj miniLINK VALUE 5 -300.00 300.00 0.00 % V1 W0
344 jk miniLINK VALUE 6 -300.00 300.00 0.00 % V1 W0
345 jl miniLINK VALUE 7 -300.00 300.00 0.00 % V1 W0
346 jm miniLINK LOGIC 1 0 1 0 0: OFF
1: ON
V1 W0
347 jn miniLINK LOGIC 2 0 1 0 0: OFF
1: ON
V1 W0
348 jo miniLINK LOGIC 3 0 1 0 0: OFF
1: ON
V1 W0
349 jp miniLINK LOGIC 4 0 1 0 0: OFF
1: ON
V1 W0
350 jq miniLINK LOGIC 5 0 1 0 0: OFF
1: ON
V1 W0
351 jr miniLINK LOGIC 6 0 1 0 0: OFF
1: ON
V1 W0
352 js miniLINK LOGIC 7 0 1 0 0: OFF
1: ON
V1 W0
353 jt miniLINK LOGIC 8 0 1 0 0: OFF
1: ON
V1 W0
355 jv JOG/SLACK RAMP RATE 0.1 600.0 1.0 s V0 W0
357 jx SPEED LOOP MAX DEMAND 0.00 105.00 105.00 % V0 W0
358 jy SPEED LOOP MIN DEMAND -105.00 0.00 -105.00 % V0 W0
359 jz DIGITAL OUTPUT 1 INVERTED 0 1 0 V0 W0
360 k0 DIGITAL OUTPUT 2 INVERTED 0 1 0 V0 W0
361 k1 DIGITAL OUTPUT 3 INVERTED 0 1 0 V0 W0
362 k2 ANALOG OUTPUT 1 MODULUS 0 1 0 V0 W0
363 k3 ANALOG OUTPUT 2 MODULUS 0 1 0 V0 W0
364 k4 LINK 1 SOURCE TAG -1298 1298 0 V0 W2
365 k5 LINK 1 DESTINATION TAG 0 1298 0 V0 W2
366 k6 LINK 2 SOURCE TAG -1298 1298 0 V0 W2
367 k7 LINK 2 DESTINATION TAG 0 1298 0 V0 W2
368 k8 LINK 3 SOURCE TAG -1298 1298 0 V0 W2
369 k9 LINK 3 DESTINATION TAG 0 1298 0 V0 W2
370 ka LINK 4 SOURCE TAG -1298 1298 0 V0 W2
371 kb LINK 4 DESTINATION TAG 0 1298 0 V0 W2
374 ke SEQUENCING SYSTEM RESET 0 1 0 V0 W4
375 kf SETPOINT SUM 1 LIMIT 0.00 200.00 105.00 % V0 W0