590 Series DC Digital Drive Parameter Specification Tables
C-25
Tag Mn Function Block Name Parameter Name Minimum Maximum Default Units Range Notes
5: UNLOCKED
6: FAIL
1199 kD PLL PHASE ERROR 0.00 0.00 0.00 V0 W4
1201 kF PLL PLL MAINS FREQ 0.00 0.00 0.00 V0 W4
1204 kI SEQUENCING COMMS TIMEOUT 0.0 60.0 0.0 s V0 W0
1220 kY CONFIGURE DRIVE AUTOMATIC SAVE 0 1 0 V0 W0
1226 lE AUTOTUNE STATE 0 3 0 0: IDLE
1: RUNNING
2: SUCCESS
3: FAILED
V1 W4
1227 lF ENCODER 1 SPEED FEEDBACK 0.0 0.0 0.0 % V0 W4
1238 lQ DIGITAL INPUT 4 OUTPUT 0.00 0.00 0.00 % V0 W4
1239 lR DIGITAL INPUT 4 VALUE FOR TRUE -300.00 300.00 0.01 % V0 W0
1240 lS DIGITAL INPUT 4 VALUE FOR FALSE -300.00 300.00 0.00 % V0 W0
1241 lT DIGITAL INPUT 5 OUTPUT 0.00 0.00 0.00 % V0 W4
1242 lU DIGITAL INPUT 5 VALUE FOR TRUE -300.00 300.00 0.01 % V0 W0
1243 lV DIGITAL INPUT 5 VALUE FOR FALSE -300.00 300.00 0.00 % V0 W0
1246 lY ALARM HISTORY ALARM 1 NEWEST 0x0000 0xFFFF 0x0000 V0 W4
1247 lZ ALARM HISTORY ALARM 2 0x0000 0xFFFF 0x0000 V0 W4
1248 mA ALARM HISTORY ALARM 3 0x0000 0xFFFF 0x0000 V0 W4
1249 mB ALARM HISTORY ALARM 4 0x0000 0xFFFF 0x0000 V0 W4
1250 mC ALARM HISTORY ALARM 5 0x0000 0xFFFF 0x0000 V0 W4
1251 mD ALARM HISTORY ALARM 6 0x0000 0xFFFF 0x0000 V0 W4
1252 mE ALARM HISTORY ALARM 7 0x0000 0xFFFF 0x0000 V0 W4
1253 mF ALARM HISTORY ALARM 8 0x0000 0xFFFF 0x0000 V0 W4
1254 mG ALARM HISTORY ALARM 9 0x0000 0xFFFF 0x0000 V0 W4
1255 mH ALARM HISTORY ALARM 10 OLDEST 0x0000 0xFFFF 0x0000 V0 W4
1267 mT ENCODER 1 ENCODER TYPE 0 1 1 0: CLOCK/DIRECTION
1: QUADRATURE
V0 W1
1276 nC AUTOTUNE ERROR TYPE 0 12 0 0: NO ERROR
1: OVER SPEED
2: FIELD ERROR
3: PULSE WIDTH
4: OVER CURRENT
5: TIMEOUT
6: AUTOTUNE
ABORTED
7: FIRING ANGLE
8: PEAK/AVER. RATIO
9: UNBALANCED BRID.
V1 W4