EasyManua.ls Logo

Parker 591C - Page 269

Parker 591C
401 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D-20 Programming 590 Series DC Digital Drive
ALARMS
Parameter Tag Range
HEALTH LED 122 FALSE / TRUE
State of Health LED on Keypad.
HEALTH WORD 115 0x0000 to 0xFFFF
The hexadecimal sum of any alarms present. Refer to Chapter 7: “Trips and Fault Finding” - Alarm Messages.
HEALTH STORE 116 0x0000 to 0xFFFF
The hexadecimal value of the first (or only) alarm. Refer to Chapter 7: “Trips and Fault Finding” - Alarm Messages.
REMOTE TRIP 542 FALSE / TRUE
The state of Remote Trip.
STALL TRIP 112 FALSE / TRUE
Armature current is above STALL THRESHOLD and AT ZERO SPEED but not AT ZERO SETPOINT.

Table of Contents