D-52 Programming 590 Series DC Digital Drive
DIGITAL OUTPUTS
These function block allows
you to output digital
parameters within the
software to other
equipment.
A digital output can be
configured to link to any
digital value within the
software system and to
output information
depending upon the status of
that value.
DIGITAL OUTPUTS
Parameter Tag Range
INPUT 683, 684, 685
⎯.xx %
The unprocessed value to output.
INVERTED 359, 360, 361 FALSE / TRUE
Selects to invert the output when TRUE.
THRESHOLD (>) 195, 196, 197 -300.00 to 300.00 %
The threshold which the input value must exceed to set the output to TRUE.
MODULUS 43, 44, 45 FALSE / TRUE
When TRUE, the absolute value of INPUT is used for the threshold test.
DIGOUT 1 (B5) to DIGOUT 3 (B7) 74, 75, 76 OFF / ON
The actual Boolean value sent to the output terminal.