590 Series DC Digital Drive Programming
D-73
MAIN PORT (P1)
Parameter Tag Range
UNIT ID (UID) 139
0 to 15
The Parker SSD Drives protocol unit identity address.
ESP SUP. (ASCII) 152
ENABLED / DISABLED
Reserved for future use.
CHANGEBAND (BIN) 144
0.00 to 100.00 %
Reserved for future use.
PNO.7 142
0x0000 to 0xFFFF
Reserved for future use.
ERROR REPORT 158
0x0000 to 0xFFFF
Displays the last error as a hexadecimal code. Writing any value to this parameter will set the value to >00C0 (No Error). Refer to Appendix A:
“Serial Communications” - Reference for a list of codes.
REPLY DELAY 695
0 to 255 ms
A programmable delay inserted by the drive before replying to a request.
ENABLED 146 ENABLED / DISABLED
Enables Main Port (P1) operation.
PARITY 334 ODD / EVEN
Selects odd or even parity.
OPTION ADDRESS 499 0 to 32767
Refer to Profibus Communications Option board Technical Manual for further details.
OPTION VERSION 303 -.xx
Refer to Profibus Communications Option board Technical Manual for further details.