590 Series DC Digital Drive Programming
D-89
PROFILED GAIN
Parameter Tag Range
MODE 473 0 to 4
This determines the shape of the proportional gain profile. The higher the setting, the steeper the curve of the profiled gain.
For Mode = 0, Profiled Gain = constant = P.
For Mode = 1, Profiled Gain = A * (diameter - min diameter) + B.
For Mode = 2, Profiled Gain = A * (diameter - min diameter)^2 + B.
For Mode = 3, Profiled Gain = A * (diameter - min diameter)^3 + B.
For Mode = 4, Profiled Gain = A * (diameter - min diameter)^4 + B.
PROFILED GAIN 475
.x
The proportional gain after profiling by a profiler block which varies the gain versus diameter. This is primarily to be used with Speed Profiled
Winders for compensation against varying diameter and therefore inertia.
When MODE is not ZERO (see above) this overrides the P gain above.
When MODE = 0, then PROFILED GAIN = PROP. GAIN.