590 Series DC Digital Drive Programming
D-95
Functional Description
RAMP INPUT
Jog /
I/P
O/P
1
0
RAMP DECEL TIME
RAMP ACCEL TIME
RAMP HOLD
AUTO RESET
EXTERNAL RESET
RESET VALUE
Slack
"S" RAMP
0
I/P
O/P
t
% S-RAMP
RAMPING THRESH.
RAMPING
RAMP OUTPUT
INVERT
+
-

Table of Contents