590 Series DC Digital Drive Programming
D-103
SETPOINT SUM
Parameter Tag Range
SIGN 0 292, 705 NEGATIVE / POSITIVE
Polarity for INPUT 0.
LIMIT 375, 449 0.00 to 200.00 %
The Setpoint Sum programmable limit is symmetrical and has the range 0.00% to 200.00%. The limit is applied both to the intermediate results of
the RATIO calculation and the total output.
-1
LIMIT
INPUT 2
INPUT 1
INPUT 0
SPT SUM OUTPUT 86, 451
⎯.xx %
The sum of input 0, 1 and 2 after the limit clamp.
OUTPUT 1 (in SETPOINT SUM 1)
STPT SUM 2 OUT 1 (in SETPOINT
SUM2)
702, 492
⎯.xx %
An additional output provided to gain access to Input 1 channel sub-calculations. The result of (INPUT 1 x RATIO 1) / DIVIDER 1 clamped to
within ± LIMIT.
OUTPUT 0 (in SETPOINT SUM 1)
STPT SUM 2 OUT 0
(in SETPOINT
SUM 2)
703, 491
⎯.xx %
An additional output provided to gain access to Input 0 channel sub-calculations. The result of (INPUT 0 x RATIO 0) / DIVIDER 0 clamped to
within ± LIMIT.