590 Series DC Digital Drive
Technical Specifications E-5
Environmental Details
Operating Temperature
0°C to +55°C (see the “Cooling” table)
Operating temperature is defined as the ambient temperature to the immediate surround of the Converter, when the Converter
and other equipment adjacent to it is operating at worst case conditions.
Storage Temperature
-25°C to +55°C
Shipping Temperature
-25°C to +70 °C
Product Enclosure Rating Cubicle Mounted
IP00 (Europe)
UL Open Type (North America/Canada)
Altitude If >500 metres above sea level, derate Motor Power rating by 1% per 200 metres to a maximum of 5,000 metres
Humidity
Maximum 85% relative humidity at 40°C non-condensing
Atmosphere Non flammable, non corrosive and dust free
Vibration Test Fc of EN60068-2-6
10Hz<=f<=57Hz sinusoidal 0.075mm amplitude
57Hz<=f<=150Hz sinusoidal 1g
10 sweep cycles per axis on each of three mutually perpendicular axis
Climatic Conditions Class 3k3, as defined by EN60721-3-3 (1995)
Safety
Europe EN61800-5 : 2003, when fitted inside a cubicle
North America/Canada
UL508C
Overvoltage Category Overvoltage Category III (3-phase supply), Overvoltage Category II (auxiliary supply)
Pollution Degree Pollution Degree 2
EMC Compliance
All models
European Community Directive 2004/108/EC
All models
EN61800-3 (2004) Table 17 : conducted emissions when installed in accordance with the instructions in Chapter 3. Refer to
"Mounting the Drive".
EN61800-3 (2004) Immunity requirements:
Maximum controlled speed (with feedback option) deviation = ±1%
Maximum controlled armature current deviation = ±1%
Maximum controlled field current deviation = ±10%
Maximum line impedance 3% for compliance (defined as percentage drop in line-to-neutral voltage when rated dc current
flows in armature output)
EN61800-3 (2004) Table 18 Radiated emissions
If fitted with external filters EN61800-3 (2004) restricted distribution: conducted emissions