5.4 Speed configuration
The speed monitor is configured using the rotary knob on the device.
To monitor e.g. various operating modes you can configure up to 16 parameter sets (P0 ...
P15) with a max. of 9 switch functions (F1 ... F9) each.
In addition, special functions may be configured for each parameter set (except in Select
mode "None") (see chapter Special functions [ 35]).
One of the 16 parameter sets is selected via 4 select inputs SEL1 (Y10), SEL2 (Y11), SEL4
(Y12), SEL8 (Y13).
The switching functions are monitored simultaneously.
Each of a switching function's 16 parameters can be configured as
} Standstill limit
} Speed limit
} Upper or lower limit of speed range
} Right-hand direction monitoring
} Left-hand direction monitoring
} Position monitoring 1 to 4 with width of position window 1 to 4
} Static value "On" or "Off"
Each output can be assigned a switch function or an area. The results of the switch func-
tions can also be linked together logically. A switch function can be assigned to several out-
puts. A switch delay [ 26], the start type [ 24] and Synchronous start [ 25] can be
configured for each output.
If only one parameter set is used, configure the mode "Select inputs: None". The select in-
puts will then be ignored.
INFORMATION
2 basic configurations are available for standard applications, for simple
configuration within the display menu. A basic configuration contains limited
menu functions adapted for standard applications, with partly pre-defined
parameters. Further information about basic configurations can be found in
this chapter, under "Basic configuration".
Example configuration:
2 parameter sets for 2 operating modes are configured:
} Set-up: P0
} Automatic mode: P1
The parameter set P0 is used to monitor a reduced speed.
The parameter set P1, "Automatic mode", is selected for speed monitoring (selection via
the Select inputs, see next chapter "Select inputs").
The following switching functions are configured for the parameter set P0:
} F1: Standstill 2 Hz
} F2: Overspeed: 50Hz
} F3: Warning threshold: 50Hz