Display menu - Configuration
Operating Manual PNOZ s30
1001715-EN-19
| 83
8.7.8 Menu messages
Level Menu designation Description Display/Settings
- Actual error mes-
sages
Up to 8 errors are displayed.
Recoverable errors: Level 2, 3 and
4
(user-recoverable)
System error: Level 2 and 3
(internal error, information for Pilz
Service).
The error messages can be hid-
den with "Escape".
Repairable error:
Level 2:
1st line: Seq. No. "Err.:", error number
2nd + 3rd line: Plain text to describe er-
ror for the user
Level 3:
1st line: Seq. No. "Repairable"
2nd line: "System Time"
3rd line: System time when the error
occurred
Level 4:
Information for Pilz Service
System error:
Level 2:
1st line: Seq. No. "Err.:", error number
2nd line: "System Error"
3rd line: System time when the error
occurred
Level 3:
Information for Pilz Service
- Error Faulty Signal:
A/A B/B Z/Z
Error message: Incorrect signal at
one or more tracks.
The message
- is continually updated.
- can be ignored temporarily.
- AB frequency devi-
ation
Error message: Frequency differ-
ence between the proximity
switches on tracks A and B
The message
- is continually updated
- can be ignored temporarily
- Chip card mes-
sages