Function description
Operating Manual PNOZ s30
1001715-EN-19
| 37
5.4.4 Basic configuration
Two basic configurations are available for standard applications, for simple configuration
within the display menu. A basic configuration contains limited menu functions adapted for
standard applications, with partly pre-defined parameters.
The following basic configurations are available:
Basic configuration 1: Ini pnp pnp (proximity switch)
Pre-defined settings and configuration options:
} Encoder type
2 pnp type proximity switches
} Switch functions
– Standstill (F1)
Standstill frequency configurable in Hz
Default: 2 Hz
– Speed (F2)
Max. frequency (v max) configurable in Hz
Default: 500 Hz
} Parameter set/select input
P0, select inputs are ignored ("None" mode")
} Hysteresis
Standstill and speed, 2 % each
} Output assignment
– Standstill (F1): Relay output Rel. 1 and semiconductor output Out 1
– Speed (F2): Relay output Rel. 2 and semiconductor output Out 2
} Start mode
– Rel. 1, Rel. 2 Out 1, Out 2: Automatic start
} Switch delay
None
} Max. encoder frequency
3.5 kHz
Basic configuration 2: Encoder
} Encoder type
Encoder
– Encoder type configurable