• Compatibility
Compatibility is maintained by hosts and routers taking appropriate actions
depending on the versions of MLD operating on hosts and routers within a
network. The allowed selection is MLD-Auto, Forced MLDv1, Forced MLDv2,
default compatibility value is MLD-Auto.
• PRI
(PRI) Priority of Interface. It indicates the MLD control frame priority level
generated by the system. These values can be used to prioritize different classes
of traffic. The allowed range is 0 (best effort) to 7 (highest), default interface
priority value is 0
• RV
Robustness Variable. The Robustness Variable allows tuning for the expected
packet loss on a network. The allowed range is 1 to 255, default robustness
variable value is 2.
• QI
Query Interval. The Query Interval is the interval between General Queries sent
by the Querier. The allowed range is 1 to 31744 seconds, default query interval is
125 seconds.
• QRI
Query Response Interval. The Max Response Time used to calculate the Max
Resp Code inserted into the periodic General Queries. The allowed range is 0 to
31744 in tenths of seconds, default query response interval is 100 in tenths of
seconds (10 seconds).
• LLQI (LMQI for IGMP)
Last Member Query Interval. The Last Member Query Time is the time value
represented by the Last Member Query Interval, multiplied by the Last Member
Query Count. The allowed range is 0 to 31744 in tenths of seconds, default last
member query interval is 10 in tenths of seconds (1 second).
• URI
Unsolicited Report Interval. The Unsolicited Report Interval is the time between
repetitions of a host's initial report of membership in a group. The allowed range
is 0 to 31744 seconds, default unsolicited report interval is 1 second.
Buttons
: Refreshes the displayed table starting from the "VLAN" input fields.
: Updates the table starting from the first entry in the VLAN Table, i.e. the entry with the lowest VLAN ID.
: Updates the table, starting with the entry after the last entry currently displayed.
:Click to add new MLD VLAN. Specify the VID and configure the new entry.
Click "Save". The specific MLD VLAN starts working after the corresponding static VLAN is also created.
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.

Table of Contents

Other manuals for Planet IGS-10020 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Planet IGS-10020 Series and is the answer not in the manual?

Planet IGS-10020 Series Specifications

General IconGeneral
BrandPlanet
ModelIGS-10020 Series
CategoryNetwork Router
LanguageEnglish

Related product manuals