Appendix C
A-85
POLYLINK FLOWMETER DATA LINK
UTILITY
PolyLink is a universal communications utility for Polysonics flowmeters, replacing PXU.
It provides the following remote functions (depending on the flowmeter model):
!
Monitoring and configuring (Section A.3)
!
Data log file downloads and deletions (Section A.5)
!
Software uploads (Section A.6)
!
Graphical signal analysis (Section A.7)
Table A-1 lists the available PolyLink features by flowmeter model as of the date of this printing:
Table A-1
PolyLink Feature Availability
Flowmeter
Model
Remote Configuring
and Monitoring
Data log Downloads
and Deletions
Software
Uploads
Graphical Signal
Analysis
DDF3088
No
Yes
No
1
No
2
DDF4088
3
Yes
4
Yes
Yes
Yes
DDF4488
Yes
4
Yes
Yes
Yes
DDF5088
Yes
N/A
No
5
No
6
DCT-6088
Yes
4
Yes
Yes
7
No
8
DCT-7088
Yes
4
Yes
Yes
7
No
8
ISTT
Yes
4
Yes
N/A
No
ISTT-P
Yes
4
Yes
N/A
No
1
The DDF3088 may be upgraded with the HCOM utility, which is provided on the PlantCom Utility
Software diskette.
2
The graphical signal analysis feature is available through the DDF3088’s integrated keypad and display.
3
The DDF4088 must have version 1.1 or higher installed to communicate with PolyLink.
4
VT100 mode.
5
The DDF5088 may be upgraded with the Loader utility, which is provided on the PlantCom Utility
Software diskette.
6
The graphical signal analysis feature for the DDF5088 is available with the optional WinFLOW
utility.
7
The DCT series of flowmeters are upgraded with a utility provided with the upgraded software.
8
The graphical signal analysis feature for the DCT series of flowmeters is available with the
TimeGATE
utility.
PolyLink is available on the PlantCom Utility Software diskette from Polysonics or by
modem download from the Polysonics Bulletin Board System (BBS) at (713) 933-1901.
(For procedures on using the BBS, refer to the file BBS.TXT, available on the PlantCom
Utility Software diskette.) PolyLink is also available in the zipped software upload files for
the flowmeters listed in Table A-1.
NOTE:
For information on using PolyLink with a DDF5088, refer to the DDF5088
instruction manual.

Table of Contents