7088-8000
-35
Liner Inside Roughness (Menu 19)
This menu is available only if
OTHER
was selected for
the liner material in Menu 16. The liner inside
roughness of the
OTHER
material should be entered in
this menu. Data on this parameter is available from the
Cameron Hydraulic Data Book published by Ingersoll-
Rand. If
OTHER
was not selected, this menu is
available only by the direct access method and not by
scrolling. In this case, this menu functions as a view-
only display to indicate the liner inside roughness from
the flowmeter’s data base.
3.6.4 FLUID SETUP MENUS
The
FLUID
sub-menu contains the setup menus related
to the fluid being measured.
Fluid Type (Menu 20)
This menu is used to select one of the following fluid
types:
!
WATER
!
SEA WATER
!
KEROSENE
!
GASOLINE
!
FUEL OIL #2
!
CRUDE OIL
!
PROPANE
(-45°C)
!
BUTANE
(0°C)
!
OTHER
NOTE:
The selection
OTHER
denotes a fluid type not
listed. If
OTHER
is selected, the fluid sound
speed (Menu 21) and fluid viscosity
(Menu 22) must next be entered for this fluid
type.
Liner Roughness
0.001000
Fluid Type
*GASOLINE