F.4.7 TOTALIZER OPTION GROUP
The
TOTALIZER
option group is accessed by clicking on
TOTALIZER
in the Options
Column. This group contains the options related to the totalizers, including selecting the
totalizer units and the totalizer multiplier.
There are three totalizers available:
!
Positive totalizer
!
Negative totalizer
!
Net totalizer
The positive totalizer tracks the flow moving in the positive direction (from the upstream
transducer to the downstream transducer). It is not affected by flow in the opposite
(downstream) direction.
The negative totalizer tracks the flow moving in the negative direction (from the
downstream transducer to the upstream transducer). It is not affected by flow in the
opposite (upstream) direction.
The net totalizer provides the difference between the positive and negative flow values. For
example, if there are 1000 gallons of flow in the negative direction and 3000 gallons of
flow in the positive direction, the net totalizer indicates 2000 gallons of net flow.
Enable Totalizers
Any combination of totalizers may be enabled or disabled. If a totalizer is merely disabled,
it stops totalizing but is not reset to zero.
NOTE:
The totalizers can be reset by clicking on the
RESET
button in the
GRAPH
tab
(Section F.5) and clicking the appropriate check boxes.
To enable the totalizers, click on one or more of the following check boxes in the
TOTALIZER
options group:
!
NET
(net totalizer)
!
POS
(positive totalizer)
!
NEG
(negative totalizer)