4. The nominal magnet resistance is 90 Ω to 110 Ω. If the resistance measures sig-
nificantly low or open, replace the magnet, see "Eddy Current Magnet Assy Replace-
ment" on page144.
Note:The resistance of the magnets will be higher than nominal (90 Ω to 110 Ω)
when they are warm.
5. If the magnet was replaced, start a manual workout and operate the machine from
min to max resistance from low to high speed (SPM
1
) . Verify normal machine res-
istance operation.
6. Replace all removed covers, see "Covers and Panels Replacement" on page75.