measure‐
ments
The
‘Calculating measurements’
menu lets you
access the options available in the installation part.
Outputs The
‘Outputs’
menu lets you access the options
available in the installation part.
Conditions The
‘Conditions’
menu lets you access the options
available in the installation part.
Communica‐
tion
The
‘Communication’
menu lets you access the
options available in the installation part.
Factory set‐
tings
The
‘Factory settings’
menu lets you access the
options available in the installation part.
Press on the respective menu item to move to the menu
item.
8.1.1
‘Options’
menu
Press the
‘Options’
menu item to move to the menu item.
Tab. 12: Options > ‘Installation options’ sub-menu
Menu item Function
‘Installation’
locking code Enable or disable the security code to access the
‘Installation’
menu.
‘Settings’
locking code Enable or disable the security code to access the
‘Settings’
menu.
Use the installation code to lock
the
‘Settings’
level
Use the
‘Installer’
code to lock the
‘Settings’
menu
Lock the
‘Options’
menu on the
‘Settings’
level.
Lock and prevent access to the options in the
‘Settings’
menu
Press the right arrow key to move to the
‘General
configuration’
selection screen.
Tab. 13: Options > ‘General configuration’ sub-menu
Menu item Function
‘Automatically create a
parameter for each sensor’
.
If this option is enabled, a measuring parameter corresponding to the
sensor type is created when a new sensor is added. It is still possible to
change and/or delete this parameter in a second step.
This option permits faster configuration for a simplified installation.
‘Condition the flow rates only to
this parameter’
.
This option is used to separate the flow rate condition and the parameter
control. If this box is not checked, control is undertaken at sensor level
and the control levels need to be set separately for each parameter con‐
trolled. This means, for example, that the capacity is controlled differently
with acid than with chlorine. If this field is checked, only one control level
is defined for all control parameters.
‘ Condition the liquid level
sensors only to this parameter’
.
The same principle as with the previous option, but for the liquid level
sensors 4 ... 20 mA.
‘Enable the extended
configuration of the flow switch/
flow meter’
.
If this box is checked, it is possible to manage the conditioning type
between the flow switch and the flow meters to switch conditioning on or
off. The logic conditions AND / OR can then be configured in the “Condi‐
tions” menu. If this box is not checked, the OR condition is active as
standard
Setting measuring and control parameters
80