Appendix A Programming Guide
A-23
A-3.6
Macro Control Commands
MACRO CONTROL
Description
COMMANDS
ESC & f # Y
Macro ID
ESC & f # X
Macro Control
# = 0
: Start macro definition (last ID
specified)
# = 1
: Stop macro definition
# = 2
: Execute macro (last ID specified)
# = 3
: Call macro (last ID specified)
# = 4
: Enable macro for automatic
overlay (last ID specified)
# = 5
: Disable automatic overlay
# = 6
: Delete all macros
# = 7
: Delete all temporary macros
# = 8
: Delete macro (last ID specified)
# = 9
: Make macro temporary
(last ID specified)
# = 10
: Make marco permanent
(last ID specified)
Note:
For detailled informations see HP PCL 5 Technical Reference Manual.