- response: mass value in current measuring unit
space character mass space unit CR LF
Switch off continuous transmission in current measuring unit
- command understood but not accessible at this moment
- command understood and carried out
Set min checkweighing threshold
Format: DH_XXXXX CR LF, where: _ - space, XXXXX - mass format
- command not recognised (mass format incorrect)
Set max checkweighing threshold
Format: UH_XXXXX CR LF, where: _ - space, XXXXX - mass format
- command not recognised (mass format incorrect)
Give value of min checkweighing threshold
Response: DH_MASA CR LF - command carried out
1 2 3 4-12 13 14 15 16 17 18 19
D H space mass space unit space CR LF
- 9 characters, right justification
- 3 characters, left justification
Give value of max checkweighing threshold
Response: UH_MASA CR LF - command carried out
1 2 3 4-12 13 14 15 16 17 18 19
U H space mass space unit space CR LF
- 9 characters, right justification
- 3 characters, left justification
Set mass value of a single item (for PARTS COUNTING mode)
Format: SM_XXXXX CR LF, where: _ - space, XXXXX - mass format