RADWIN2000CPlusUserManual Release3.5.70 6‐39
TelnetAccesstotheMasterODU Chapter6
SupportedMasterODUTelnetcommandsareshowninTable 6‐5toTable 6‐7.
Table6‐5:MasterODUTelnet‐DisplayCommands
Command Explanation
displayinventor y
DisplaysODUproductname,Name,Location,
hardwareandsoftwarerevisions,uptime,MAC
address.
displaymanagement DisplaysIP,subnet,Gateway,Trapstable
displaylink<param:all,reg,unreg> DisplaysallstaticdetailsaboutthesectororHSU
displayethernet DisplaysPorttable(State,Statusandaction)
displayethernet_errors DisplaysCablestatistics
displayntp DisplaysTime,ServerandOffset
displayPM<interface:AIR,LAN1>
<interval:current,day,month>
Showstheperformancemonitortablesforeach
interfaceaccordingtouserdefinedmonitoring
intervals
displaybands Displaysavailablebands
Table6‐6:MasterODUTelnet‐SetImmediateCommands
Command Explanation
setip<ipaddr><subnetMask>
<gateway>
SettheODUIPaddress,subnetmaskandgateway .
TheusermustresettheODUafterthecommand
completion
settrap<index:1‐10><ipaddr>
<port:0‐65535>
Setaspecifictrapfromthetrapstable(e.g.settrap3
192.168..101162)
setreadpw<oldpasswd><passwd> Setthereadaccesspassword(ReadCommunity)
setwritepw<oldpasswd><passwd>
Settheread‐writeaccesspassword(Read‐Write
Community)
settrappw<oldpasswd><passwd> SetthetrapCommunitystring
settpc<power:Valuebetween
minimalTxpower,andmaximalTx
power>
SettheODUTxPower.Ifawrongvalueisentered,
bothminandmaxvaluesshallbedisplayedinthe
errorreply
setname<newname> Setthenameofthelink
setlocation<newlocation> Setthenameofthelocation
setcontact<newcontact> Setthenameofthesitemanager
setethernet<port:LAN1>
<mode:AUTO,10H,10F,100H,100F,D
ISABLE>
SetthemodeandspeedoftheEthernetport