RADWIN2000CPlusUserManual Release3.5.70 D‐1
AppendixD:
RFExposure
Theantennasusedforthefollowingtransmittersmustbeinstalledsoastoprovidea
minimumseparationdistancefrombystandersasspecifiedinthefollowingtables:
TableD‐1:SafetyDistancesforRADWIN2000CPlusFCCandICProducts
Frequency
Band
[GHz]
FCCID ICID
Antennagain
[dBi]
Min.Safety
Distance[cm]
5.8 Q3KRW5XMOD 5100A‐RW5XMOD 32 354
5.8 Q3KRW5XMOD 5100A‐RW5XMOD 29 251
5.8 Q3KRW5XMOD 5100A‐RW5XMOD 24 141
5.8 Q3KRW5XMOD 5100A‐RW5XMOD 16 60
5.8 Q3KRW5XMOD 5100A‐RW5XMOD Alllinks 20
5.3/5.4 Q3KRW5XMOD 5100A‐RW5XMOD Allgains 20
4.9 Q3KRW5XMOD 5100A‐RW5XMOD 32,29 96
4.9 Q3KRW5XMOD 5100A‐RW5XMOD 24 72
4.9 Q3KRW5XMOD 5100A‐RW5XMOD 16,15.5 31
4.9 Q3KRW5XMOD 5100A‐RW5XMOD 14,13 24
4.9 Q3KRW5XMOD 5100A‐RW5XMOD 12,11 20
2.4 Q3KRW24MOD 5100A‐RW24MOD 20 53
2.4 Q3KRW24MOD 5100A‐RW24MOD 17.5 43
2.4 Q3KRW24MOD 5100A‐RW24MOD 9,8,6.3 20

Table of Contents