RADWIN2000CPlusUserManual Release3.5.70 7‐13
Management Chapter7
3.TypethenewCommunitystringandre‐typetoconfirm.Acommunitystringmust
containatleastfiveandnomorethan32charactersexcludingSPACE,TAB,andany
of“>#@|*?;."
4.ClickOKtosave.
EditingSNMPv3Passwords
Tocommencetheprocess,youmustenterthecurrentRead‐WriteCommunitypasswordas
showninthefirstfieldofFigure 7‐9below.ChangetheRead‐WriteandRead‐Onlypasswords
asindicated.Apasswordmustbebetween8and31characterslong.Thesamecharacter
restrictionsfortheSNMPv1communitystringsalsoapplyhere.
Figure7‐9:ChangingtheCommunityStrings/Passwords
ForgottenSNMPv1CommunityString
Iftheread‐writeCommunitystringisunknown,analternativeCommunitykeycanbeused.
ThealternativeCommunitykeyisuniqueperODUandcanbeusedonlytochangethe
Communitystrings.ThealternativeCommunitykeyissuppliedwiththeproduct,andshould
bekeptinasafeplace.
Ifboththeread‐writeCommunityandthealternativeCommunitykeyareunavailable,then
analternativeCommunitykeycanbeobtainedfromRADWINCustomerServiceusingthe
ODUserialnumberorMACaddress.Theserialnumberislocatedontheproductlabel.The
serialnumberandtheMACaddressaredisplayed
intheSiteConfigurationinventorytab.
Whenyouhavethealt ernativeCommunitykey ,clicktheForgotCommunitybuttonandenter
theAlternativeCommunitykey(Figure 7‐10).Thenchangetheread‐writeCommunitystring.