RADWIN2000CPlusUserManual Release3.5.70 B1
AppendixB:
WiringSpecifications
ODUPoECable(HBSandHSU)
TheODUPoEcableisshielded/outdoorclassCAT5e,4twistedpair24AWGterminatedwith
RJ45connectorsonbothends.AcableglandontheODUsideprovideshermeticsealing.
Thefollowingtableshowstheconnectorpinout:
TableB1:ODUPoERJ45ConnectorPinout
Function Color PoE ODU
RxN
White/Green 1 1
RxT
Green 2 2
TxT
White/Orange 3 3
TxN
Orange 6 6
Power(+)
Blue 4 4
Power(+)
White/Blue 5 5
Power()
White/Brown 7 7
Power()
Brown 8 8
TableB2:LANGbEPoERJ45ConnectorPinout
Function Color PoE LAN
TxRxA
White/Green 1 1
TxRxA
Green 2 2
TxRxB
White/Orange 3 3
TxRxB
Orange 6 6
TxRxC&Power(+)
Blue 4 4