RADWIN2000CPlusUserManual Release3.5.70 418
InstallingaLink Chapter4
ForanytypeofIDUODUconnection,lightningprotectionunits(LPUs)areinstalledinpairs,as
showninthenextfigure:
Figure420:Basicuseoflightningprotectors
ToinstallaLPUonapoleadjacenttoanODU(HBSorHSU):
1.MountoneLPUonthe
ODUpole,ascloseas
possibletotheODU.
2.GroundtheLPUtothe
poleusingthegrounding
lug.
3.Connectthe0.5meter
CAT5ecabletotheIDU
portoftheODU.
4.Connecttheotherendof
thecabletothetopof
theLPU.
5.TightenthetopcableLPU
glandcap.
6.ConnectthemainODU
IDUcablefromtheIDUtothebottomendoftheLPU.
7.TightenthebottomcableLPUglandcap.
8.RunthemainODUIDUcabletowardstheIDUlocation.
9.InsulatebothLPUconnections.Seethenextsection,AdditionalConsiderationsfor
Waterproofing below.