EasyManuals Logo
Home>Radwin>Radio>2000 C PLUS

Radwin 2000 C PLUS User Manual

Radwin 2000 C PLUS
297 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
RADWIN2000CPlusUserManual Release3.5.70 57
LogonErrorsandCautions Chapter5
Thefollowingtablesummarizestheseoptions:
TheNetworkManage rshouldchangethedefaultpasswordsassoonaspossi ble, particularly
ifSNMPv3istobeused.
Continuingthelogonprocedure:
5.IfyourUserTypeisnotOperator,thenchooseitnow.
6.Enterthepasswordforyourusertype.
7.IfyouareauserwithReadWritepermission,clickOptionstoentertheCommunity
optionsifrequired.
LogonErrorsandCautions
UnsupportedDevice
AttemptingtoconnecttoanunsupporteddeviceonanotherwisevalidIPaddress(for
example,aLANprinter)willresultinthefollowingerrormessage:
Table52:Usertypes,defaultpasswordsandfunction
UserType
Default
Password
Function
SNMPv1 SNMPv3
Community
Communi
tyString
Password
Default
Value
Observer admin Monitoring ReadOnly public ReadOnly public
Operator admin
Installation,
configuration
ReadWrite netman ReadWrite netman
Installer wireless
Operatorplus
setband
ReadWrite netman ReadWrite netman
Note
LeavethedefaultCommunitypasswords,netmanforreadwrite,and
publicforreadonly.
Ifyouareauserwithreadonlypermission,thenyoumayonlylogon
asObserver.
ThetwofieldsserveasSNMPv1CommunitystringsandSNMPv3pass
words.