RADWIN2000CPlusUserManual Release3.5.70 C4
MIBParameters ChapterC
<winlink1000><Section1>...<Sectionn><ParameterName>
Foreachoftheconfigurationandcontrolparameters(parameterswithreadwriteaccess),
the“Description”columndescribeswhenthenewvalueiseffective.Itisrecommendedthat
youperformtheappropriateactiontomakethevaluesaff e ctiveimmediatelyafterany
change.Whereachangeisrequiredonbothsidesofthelink,itisrecommendedthatyou
changebothsidesofthelinkfirstandthenperformtheaction.
SupportedVariablesfromtheRFC1213MIB
TableC1:SupportedVariables
Name OID Type
Access
Description
ifIndex
.1.3.6.1.2.1.2.2.1.1.x
a
Integer RO Auniquevalueforeachinterface.Itsvalue
rangesbetween1andthevalueof
ifNumber.Thevalueforeachinterfacemust
remainconstantatleastfromonere
initializationoftheentity'snetwork
managementsystemtothenextre
initialization.
ifDescr .1.3.6.1.2.1.2.2.1.2 DisplayString RO Atextualstringcontaininginformation
abouttheinterface.Thisstringshould
includethe
nameofthemanufacturer,the
productnameandtheversionofthe
hardwareinterface.
ifType .1.3.6.1.2.1.2.2.1.3 Integer RO Thetypeofinterface,distinguished
accordingtothephysical/linkprotocol(s)
immediately`below'thenetworklayerin
theprotocolstack.
ifSpeed .1.3.6.1.2.1.2.2.1.5 Gauge RO Anestimateoftheinterface'scurrent
bandwidthinbitspersecond.Forinterfaces
whichdonotvaryinbandwidthor
for
thosewherenoaccurateestimationcanbe
made,thisobjectshouldontainthe
nominalbandwidth.
ifPhysAddress .1.3.6.1.2.1.2.2.1.6 PhysAddress RO T heinterface'saddressattheprotocol
layerimmediately`below'thenetwork
layerintheprotocolstack.Forinterfaces
whichdonothavesuchanaddress(e.g.,a
serialline),thisobjectshouldcontainan
octetstringofzerolength.
ifAdminStatus .1.3.6.1.2.1.2.2.1.7 Integer RW Thedesiredstateoftheinterface.The
testing(3)stateindicatesthatno
operationalpacketscanbepassed.
ifOperStatus .1.3.6.1.2.1.2.2.1.8 Integer RO Thecurrentoperationalstat eofthe
interface.Thetesting(3)stateindicates
thatnooperationalpack etscanbepassed.
ifInOctets .1.3.6.1.2.1.2.2.1.10.x Counter RO Thetotalnumberofoctetsreceivedonthe
interface,includingframingcharacters.
ifInUcastPkts .1.3.6.1.2.1.2.2.1.11.x Counter RO Thenumberofsubnetworkunicastpackets
deliveredtoahigherlayerprotocol.
ifInNUcastPkts .1.3.6.1.2.1.2.2.1.12.x Counter RO Thenumberofnonunicast(i.e.,
subnetwork‐broadcastorsubnetwork
multicast)packetsdeliveredtoahigher
layerprotocol.
ifInErrors .1.3.6.1.2.1.2.2.1.14.x Counter RO Thenumberofinboundpacketsthat
containederrorspreventingthemfrom
beingdeliverabletoahigherlayer
protocol.