4. ToaddafurtherHSSunit:ConnectthenextavailableSYNCportfromthesecond
HSSunitindescendingorder(SYNC5inFigure 107)toSYNC1ofthethirdHSS
unit.
5. ODUsareconnectedtothethirdHSSunitfromSYNC2asshowninFigure 108,in
ascendingorder:
Figure108:CascadingthreeHSSunits
6. IffurtherODUsarerequired,observetheconventionthatadditionaleven
numberedunitsarepopulatedindescending orderfromSYNC9andodd
numberedHSSunitsarepopulatedinascendingorderfromSYNC2.
Condition2:TotalHSSCableLength
ThetotalpathoftheHSSsyncpulsemustnotexceed300m.Thisappliesnomatterhowmany
HSSunitsareused.Toillustratethemethodforcalculatingthesyncpulsepathlengthwe
showthreeexamples.Forourpurpose,let:
LmndenotethelengthoftheODUHSSunitcableatSYNCnonHSSunitm
HmbethelengthofthecablejoiningHSSunitmtoHSSunitm+1
OneHSSunitwithfivecollocatedODUs
TwocascadedHSSunitsasshowninFigure 107
Note
IfanODUisdisconnectedfromanHSSunit,thenallremainingODUsmust
bemovedupordowntomaintaintheconnectivity.
PathLength L
11
2 L
12
2 L
13
+ 2 L
14
L
15
+++=
PathLength L
11
2 L
12
2 L
13
2 L
14
+
2
+
L
15
+
H
1
2 L
29
2+ L
28
2+ L
27
L
26
+
+
++
=

Table of Contents