EasyManua.ls Logo

Radwin 2000 C PLUS - RF Planning for Dense Installations and Collocated Sites 3

Radwin 2000 C PLUS
297 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RADWIN2000CPlusUserManual Release3.5.70 35
RFPlanningforDenseInstallationsandCollocatedSites Chapter3
SelfinterferencefromcollocatedRADWINradios
Othercollocatedradiodevicesinstalledonthesamesite.
Toavoidorminimizeinterference,followtheserecommendations:
ForcollocatedRADWINunits,useanHSSunittosynchronizebetweenthem.Selecta
differentoperatingchannelsforeachcollocatedRADWINunit.
IfoneormorecollocatedunitsarenotRADWINunits,ensurethatthereisaphysical
separationofatleastthreemetersbetweenaRADWINunitandanyothercollocated
radioonthesite.
Usethelargestpossiblefrequencygapbetweentheseunits.
Choosethebestfrequencychannel(asclearaspossibleforminterference).Youmay
havetousetheChangeBandfacilityavailableforallRADWIN2000products.
Toselectafrequencychannel,movethelinktoInstallationMode(usingSiteconfigura
tion)andstarttheInstallationwizard.IntheChannelSettingswindow,usethequality
baratthebottomtohelpyouchooseabetterchannel(clearerofinterference).
UsetheSpectrumViewtooltofindthebestworkingchannel(Tools|SpectrumView).
DecreasingtheTxPowerofalinkwillreducecollocationinterference(SiteConfigura
tion|AirInterface).
Note
UsetheLinkBudgetCalculatortodeterminetheminimumTxPower
requiredtomaintainlinkstabi lity.

Table of Contents