EasyManua.ls Logo

Radwin 2000 C PLUS - Terminology

Radwin 2000 C PLUS
297 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RADWIN2000CPlusUserManual Release3.5.70 13
Terminology Chapter1
Terminology
•UniversalbandsrefertoRADWINUniversalbands.
•3.Xor3.XGHzreferstothefrequencyrange3.33.8GHz
•BRSreferstothe2.5GHzbandsubjecttothe FCCBRSregulations
A3.XODUisanODUpreconfiguredtooperateinthe3.XGHzlicensedbands
A3.XLinkinaRADWIN2000linkusingapairof3.XODUs
•HighResolutionBands‐Channelminimumstepis250KHz.appliesto3.475‐3.650GHz
IC,3.4‐3.7GHzETSIandthe3.3‐3.8GHzUniversalband.
•LowResolutionBands‐Channelminimumstepis1MHz.AppliestoFCCregulationsin
the3.650‐3.675GHzband.
Inthefield,alinktypicallyhasalocalorheadquarterssite.Typically,aserviceprovider
isthelocalorheadquarterssite.Theservicerecipientistheremotesite.
Wherethelinkiscompletelyinternaltoacorporation,thechoiceofthelocaland
remoteisjustamatterofconvenience.
Alinkthen,consistsoftwosites.
InBroadbandWirelessterminology,thelocalandremotesitesaresometimesreferred
toas“nearand“far,“HQ”and“remote”andsoon.
TheRADWIN2000CPlusclassradiosachievetheir250Mbpsthroughputbydrawingon
newtechnologydevelopedfortheRADWIN5000PointtoMultipointseries.Therefore
thesitesarenotsymmetrical.Thelocalsitereferredtoearlier,usesabasestationradio
(HBS)asthelinkMasterODUandtheremotesiteusesasubscriberunit(HSU)asthe
linkSlaveODU.
TheHBS/HSUandmaster/ slaveterminologywillbeusedthroughoutthemanualboth
todescribethetwolinksiteswithoutfurthercomment.
ThelinkisnormallyconfiguredandmanagedusingaPC,themanagingcomputercon
nectedtotheMasterODU.(Thepreciserequirementsforthemanagingcomputerare
setoutonpage 41).ItmayalsobeconnectedtotheSlaveODUeitherdirectlyorover
the‐air.
Wewilloccasionallyneedtodistinguishbetweenthesitetowhichthemanaging
computerisconnected,andthesecondsite,whentheyarenotspecificallyMasterODU
orSlaveODU.Theformerwillbecalledthemanagingsiteandthelatter,theoverthe
airsite.Whichiswhich,isalwa ysdeterminedbythelocationofthemanaging
computer.
RADWIN2000CPlussupportsthreeconnectionmethodsforthemanagingcomputer:
•Local‐adirectpeertopeerconnectionbetweentheEthernetportsonthemanaging
computerandthePoEdevice.
•Network‐themanagingcomputerandthesiteAIDUorPoEdevicebelongtoaLAN
andcommunicatethrougharouterorswitch
•Overtheair‐themanagingcomputerconnectstositeBviatheairinterface
ThemanagingcomputerisconnectedtothelinkthroughaPoEdevice.

Table of Contents