RADWIN2000CPlusUserManual Release3.5.70 716
Management Chapter7
Ethernet
Figure713:SettingEthernetservices
HBSAgingTime
TheHBS(MasterODU)worksinBridgeMode.InBridgemodetheODUperformsboth
learningandaging,forwardingonlyrelevantpacketsoverthesector.Theagingtimeofthe
ODUisbydefault,300seconds.
EthernetPortsConfiguration
TheODUEthernetportmodeisconfigurableforlinespeed(10/100/1000BaseT)andduplex
mode(halforfullduplex).
Linespeed1000BaseTisonlyavailableiftheODUisconnectedtoAGbEPoEdevice.
.
AnAutoDetectfeatureisprovided,wherebythelinespeedandduplexmodearedetected
automaticallyusingautonegotiation.Usemanualconfigurationwhenattachedexternal
equipmentdoesnotsupportautonegotiation.ThedefaultsettingisAutoDetect.
TheiconnexttotheCRCerrorcountmaybeclickedtoresetthe
countertozero.