RADWIN2000CPlusUserManual Release3.5.70 A6
ODU‐HBSandHSU ChapterA
ThefollowingMaxTxPowerlimitationsapplytoallproductssupportingthe3.5GHzETSI
band:
Management
Environmental
6.4
ETSI
5.9286.400
5/10 /
20
No Lowtemperature,to‐35°C
Universal
5.8956.4050 10
No N/A
5.8906.410 20
5.7256.400
5/10 /
20/40
No N/ALowtemperature,to‐55°C
OccupiedSub
Band
GHz
Center
Frequency
GHz
Mode
Channel
Bandwidth
MHz
MaxTx
Power
dBm
Frequency
Step
KHz
3.4033.490 3.4133.480
Inactive 5,10,20
17
2503.4703.610 3.4803.600 23(†)
3.5903.710 3.6003.700 25(‡)
Note
(†)The3.480GHzfrequencyisoverlapped,occurringintwodierentbands
asshown.Ifyouwishtousethe3.480GHzfreque ncy,youshouldsetMax
TXPowerto17dBm.
(‡)The3.600GHzfrequencyisoverlapped,occurringintwodierentbands
asshown.Ifyouwishtousethe3.600GHzfreque ncy,youshouldsetMax
TXPowerto23dBm.
ManagementApplication(perlink)
RADWINManager
Protocol
SNMPandTelnet
NMS
RADWINNMS‐RNMS
OperatingTemperatures
HBS/HSU:‐35°Cto+60°C/‐31°Fto+140°F
Humidity
HBS/HSU:Upto100%noncondensing,IP67
Storage
40°to85°C/‐40°Fto185°F
Band
(GHz)
Regulation
Occupied
FrequencyRange
(GHz)
CBW
(MHz)
DFS? Compliance(Notes)