RADWIN2000CPlusUserManual Release3.5.70 C12
PrivateMIBParameters ChapterC
winlink1000OduAirChannelBWTabl
e
N/A ChannelBandwidthstable.
winlink1000OduAirChannelBWEntr
y
N/A ChannelBandwidthtableentry.INDEX{
winlink1000OduAirChannelBWIndex}
winlink1000OduAirChannelBWInde
x
1.3.6.1.4.1.4458.1000.1.5.2
5.1.1
Integer RO ChannelBandwidthindex.
winlink1000OduAirChannelBWAvail 1.3.6.1.4.1.4458.1000.1.5.2
5.1.2
Integer RO ChannelBandwidthavailabilityproduct
specific.Optionsare:Notsupportedsupported
withmanualchannelselectionsupportedwith
AutomaticChannelSelection.
winlink1000OduAirChannelsAdmin
State
1.3.6.1.4.1.4458.1000.1.5.2
5.1.3
DisplayString RO Channels'availabilityperCBW.
winlink1000OduAirChannelBWHSS
ATDDConflictPerCBW
1.3.6.1.4.1.4458.1000.1.5.2
5.1.4
Integer RO IndicationforpossibleLinkdropperCBWdueto
conflictbetweenHSSandATDD.
winlink1000OduAirChannelBWMin
RatioForSupporting
1.3.6.1.4.1.4458.1000.1.5.2
5.1.5
Integer RO MinimalTXratiothatmaybeusedbytheHSM
andstillenableproperoperationofthe
aforementionedCBW.
winlink1000OduAirChannelBWMax
RatioForSupporting
1.3.6.1.4.1.4458.1000.1.5.2
5.1.6
Integer RO MaximalTXratiothatmaybeused bytheHSM
andstillenableproperoperationofthe
aforementionedCBW.
winlink1000OduAirRFD 1.3.6.1.4.1.4458.1000.1.5.2
6
Integer RO Currentradioframedurationinmicroseconds .
winlink1000OduAirRatesTable N/A AirRateindexestableforcurrentchannel
bandwidth.
winlink1000OduAirRatesEntry N/A AirRateindexestableentry.INDEX{
winlink1000OduAirRatesIndex}
winlink1000OduAirRatesIndex RO AirRateindex.
winlink1000OduAirRatesAvail RO AirRateavailabilitydependingonairinterface
conditions.
winlink1000OduAirDesiredRateIdx 1.3.6.1.4.1.4458.1000.1.5.2
8
Integer RW RequiredAirRateindex.0reservedforAdaptive
Rate.Achangeiseffectiveimmediatelyafter
Setoperationtothemastersidewhilethelink
isup.
winlink1000OduAirLinkDistance 1.3.6.1.4.1.4458.1000.1.5.2
9
Integer RO Linkdistanceinmeters.Avalueof‐1indicates
anillegalvalueandisalsousedwhenalinkis
notestablished.
winlink1000OduAirLinkWorkingMo
de
1.3.6.1.4.1.4458.1000.1.5.3
0
Integer RO Linkworkingmodeasaresultofcomparing
versionsofbothsidesofthelink.Possible
modesare:Unknown‐nolinkNormal‐versions
onbothsidesareidenticalwithfull
compatibilitywithrestrictedcompatibilityor
versionsonbothsidesaredifferentwith
softwareupgradeorversionsincompatibility.
winlink1000OduAirMajorLinkIfVersi
on
1.3.6.1.4.1.4458.1000.1.5.3
1
Integer RO Majorlinkinterfaceversion
winlink1000OduAirMinorLinkIfVersi
on
1.3.6.1.4.1.4458.1000.1.5.3
2
Integer RO Minorlinkinterfaceversion
winlink1000OduAirHssDesiredOpSt
ate
1.3.6.1.4.1.4458.1000.1.5.4
0.1
Integer RW RequiredHubSiteSynchronizationoperating
state.
winlink1000OduAirHssCurrentOpSt
ate
1.3.6.1.4.1.4458.1000.1.5.4
0.2
Integer RO CurrentHubSiteSynchronizationoperating
state.
winlink1000OduAirHssSyncStatus 1.3.6.1.4.1.4458.1000.1.5.4
0.3
Integer RO HubSiteSynchronizationsyncstatus.
TableC2:PrivateMIBParameters(Sheet7of32)