EasyManuals Logo

Radwin 2000 C PLUS User Manual

Radwin 2000 C PLUS
297 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #252 background imageLoading...
Page #252 background image
RADWIN2000CPlusUserManual Release3.5.70 C19
PrivateMIBParameters ChapterC
winlink1000OduPerfMonCurrEntry N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}
winlink1000OduPerfMonCurrUAS 1.3.6.1.4.1.4458.1000.1.6.1.
1.1
Gauge RO ThecurrentnumberofUnavailableSeconds
startingfromthepresent15minutesperiod.
winlink1000OduPerfMonCurrES 1.3.6.1.4.1.4458.1000.1.6.1.
1.2
Gauge RO CurrentnumberofErroredSecondsstarting
fromthepresent15minutesperiod.
winlink1000OduPerfMonCurrSES 1.3.6.1.4.1.4458.1000.1.6.1.
1.3
Gauge RO CurrentnumberofSeverelyErroredSeconds
startingfromthepresent15minutesperiod.
winlink1000OduPerfMonCurrBBE 1.3.6.1.4.1.4458.1000.1.6.1.
1.4
Gauge RO CurrentnumberofBackgroundBlockErrors
startingfromthepresent15minutesperiod.
winlink1000OduPerfMonCurrIntegri
ty
1.3.6.1.4.1.4458.1000.1.6.1.
1.5
Integer RO Indicatestheintegrityoftheentry.
winlink1000OduPerfMonCurrComp
ressed
1.3.6.1.4.1.4458.1000.1.6.1.
1.6
OctetString RO Holdsacompressedstringofalldataper
interface.CompressedAirInterfaceStructure
(sizeinbrackets):UAS(4)ES(4)SES(4)BBE
(4)Integrity(1)MinRSL(1)MaxRSL(1)
RSLThresh1Exceeded(4)RSLThresh2Exceeded
(4)MinTSL(1)MaxTSL(1)TSLThresh1Exceed
(4)BBERThresh1Exceed(4)RxMBytes(4)
TxMBytes(4)EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)Compressed
EtherentODUinterface(sizeinbrackets):UAS
(4)ES(4)SES(4)BBE(4)Integrity(1)
RxMBytes(4)TxMBytes(4)
EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)ActiveSeconds(4)
winlink1000OduPerfMonIntervalTa
ble
N/A Thistabledefines/keepsthecountersofthelast
day(inresolutionof15minintervals).
winlink1000OduPerfMonIntervalEn
try
N/A ThisisanentryintheIntervalTable.INDEX
{ifIndexwinlink1000OduPerfMonIntervalIdx}
winlink1000OduPerfMonIntervalIdx RO Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.
winlink1000OduPerfMonIntervalUA
S
RO ThecurrentnumberofUnavailableSecondsper
interval.
winlink1000OduPerfMonIntervalES RO CurrentnumberofErroredSecondsperinterval.
winlink1000OduPerfMonIntervalSE
S
RO CurrentnumberofSeverelyErroredSecondsper
interval.
winlink1000OduPerfMonIntervalBB
E
RO CurrentnumberofBackgroundBlockErrorsper
interval.
winlink1000OduPerfMonIntervalInt
egrity
RO Indicatestheintegrityoftheentryperinterval.
winlink1000OduPerfMonIntervalCo
mpressed
RO Holdsacompressedstringofalldataper
interface.CompressedAirInterfaceStructure
(sizeinbrackets):UAS(4)ES(4)SES(4)BBE
(4)Integrity(1)MinRSL(1)MaxRSL(1)
RSLThresh1Exceeded(4)RSLThresh2Exceeded
(4)MinTSL(1)MaxTSL(1)TSLThresh1Exceed
(4)BBERThresh1Exceed(4)RxMBytes(4)
TxMBytes(4)EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)Compressed
EtherentODUinterface(sizeinbrackets):UAS
(4)ES(4)SES(4)BBE(4)Integrity(1)
RxMBytes(4)TxMBytes(4)
EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)ActiveSeconds(1)
winlink1000OduPerfMonDayTable N/A Thistabledefines/keepsthecountersofthelast
month(inresolutionofdays).
winlink1000OduPerfMonDayEntry N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000OduPerfMonDayIdx}
TableC2:PrivateMIBParameters(Sheet14of32)
Name OID Type
Access
Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 2000 C PLUS and is the answer not in the manual?

Radwin 2000 C PLUS Specifications

General IconGeneral
BrandRadwin
Model2000 C PLUS
CategoryRadio
LanguageEnglish

Related product manuals